Layer 2

DescriptionTest Case IDPDTopology

Verify that ping works properly when using LACP

test_ping_011

No

Verifying IPv4 (1518) MTU

test_mtu_001

Yes

Verify MTU functionality for Jumboframe packets

test_ports_mtu_002

Yes

Enable LLDP globally and disable per-port basis

test_lldp_001

No

Verify that user can enable/disable LLDP globally

test_lldp_002

No

Verify LLDP neighbors are learnt properly with proper ChassisID, portID, system name, system

test_lldp_013

No

Verify LACP member addition and removal

test_lacp_003

No

Verify LACP functionality across reboot

test_lacp_005

No

Verify LACP functionality after link failover/failback of physical interface

test_lacp_011

No

Verify LACP functionality after removal and addition of port-channel member

test_lacp_012

No

Verify whether user can create/delete VLAN

test_vlan_001

No

Verify whether user can add/modify/delete ports to the VLAN as tagged/untagged members

test_vlan_002

No

Verify the ability to configure a port as untagged VLAN member

test_vlan_004

No

Verify the ability to configure a port as tagged VLAN member

test_vlan_005

No

Verify that the user can configure port-channel interface as untagged VLAN member

test_vlan_007

No

Verify that the user can configure port-channel interface as tagged VLAN members

test_vlan_008

No

Warm Reboot - Device configuration impact for VLAN Config

test_vlan_011

Yes

Verify whether user can configure port as untagged member of a VLAN

test_vlan_014

No

Verify whether known unicast traffic is forwarded to the destination port-channel

test_vlan_016

No

EVPN_VXLAN Configuration and show commands

test_bgp4_evpn_vxlan_001

Yes

EVPN VXLAN for known unicast, BUM traffic (eBGP) with RIF

test_bgp4_evpn_vxlan_002

Yes

EVPN VXLAN for known unicast, BUM traffic (eBGP) with SVI

test_bgp4_evpn_vxlan_003

Yes

EVPN VXLAN for known unicast traffic (eBGP) with link events and router failure - RIF

test_bgp4_evpn_vxlan_005

Yes

EVPN VXLAN for known unicast traffic (eBGP) with link events and router failure - SVI

test_bgp4_evpn_vxlan_006

Yes

EVPN VXLAN for known unicast traffic (eBGP) with link events and router failure - RPCH

test_bgp4_evpn_vxlan_007

Yes

Asymmetric IRB with EVPN eBGP

test_bgp4_evpn_vxlan_015

Yes

Asymmetric IRB with EVPN iBGP

test_bgp4_evpn_vxlan_016

Yes

MC-LAG L2 validation using port-channel configuration

test_mclag_layer2_steady_state

Yes

MC-LAG L2 validation, Bring down the member link of SPINE01

test_mclag_layer2_member_link_down

Yes

MC-LAG L2 keepalive link down

test_mclag_layer2_peer_link_down

Yes

MCLAG-L2Active Reboot

test_mclag_layer2_active_reboot

Yes

MCLAG-L2 Standby Reboot

test_mclag_layer2_standby_reboot

Yes

PD(Platform dependent) means that FTAS is designed to work with specific hardware and software configurations and may not be compatible with other platforms.

Last updated