OPBNOS R2.8
Release
  • Open Packet Broker
  • What's New?
  • Getting Started
    • Licensing
    • Limitations
    • Image Management
      • Installing OPBNOS from ONIE
      • Installing OPBNOS from USB Drive
      • Image Upgrade from OPBNOS
      • Selecting OPBNOS on next boot
      • Removing available images
      • Rebooting the Switch
    • Supported Platforms
    • Scalability
    • Downloads
  • CLI Configuration Guide
    • Configuring License
    • Configuring Hostname
    • Configuring Username
    • On-Box FlowVision
    • Configuring AAA
      • Configuring AAA
      • Configuring TACACS
      • Configuring RADIUS
    • Configure Packet Timestamping
    • Interface Management
      • Configuring Management Interface
      • Configuring Physical Interface
    • Link Layer Discovery Protocol (LLDP)
      • Enabling LLDP
      • Displaying LLDP Neighbors
    • Configuring Interface Description
    • Configuring Auto Negotiation
    • Configuring FEC
    • Configuring Maximum Transition Unit
    • Configuring Port Speed
    • Configuring Port Breakout
    • Configuring Interface Type
    • Configuring VLAN Modes
    • Configuring Loopback Mode
    • Configuring Packet Slicing
    • Configuring Ingress VLAN
    • Configuring Egress Tagging
    • Configuring Rx-only
    • Configuring Tx-only
    • Configuring An-clause
    • Configuring PortChannel
    • Configuring LAG Hash
    • Configuring Flows and Rules
      • Configuring Network Ports
      • Configuring Tool Ports
      • Configuring Flows
      • Configuring Flow Description
      • Configuring Flow Rules (NVIDIA)
      • Configuring Flow Rules (Broadcom)
      • Configuring Flow Match Expression Rules
      • Configuring Flow UDF Rules
      • Configuring Push/Pop VLAN
      • Configuring Flow Override Action(s)
      • Display Flow Information
      • Clear Flow Counters
    • Configuring GTP Flow
    • Configuring IPv6 Reachability Check
    • Configuring VXLAN Flow
    • Configuring VXLAN Stripping
    • Configuring SNMP
      • Configure SNMP community
      • Configuring SNMP Trap
      • Configuring SNMP Threshold
      • Configuring SNMP User
      • Configuring SNMP Location
      • Configuring SNMP Contact
    • Configuring SYSLOG
    • Ping
    • Traceroute
    • Configuring NTP
    • Configuring Timezone
    • Configuring sFlow
    • Display Interface Information
      • Front Panel Port Mapping
    • Display System Information
      • Interface Transceiver Information
      • System Uptime
      • Reboot Cause
      • Show Environment
      • Show System Memory
      • Show Docker Memory
      • Show Services
      • Show Platform Fan
      • Show platform pcieinfo
      • Show Platform PSU
      • Show Platform SSD
      • Show Platform Summary
      • Show Platform Syseeprom
      • Show Platform Temperature
    • Configuration Management
      • Copying Configuration from Switch
      • Copying Running and Startup Configuration
      • Saving Configuration
      • Display Configuration
      • Clearing Startup configuration
    • Zero Touch Provisioning
      • DHCP Discovery
      • ZTP Boot File
      • Enable ZTP
    • Troubleshooting
  • Aviz FlowVision Graphical User Interface Guide
    • FlowVision Controller Installation
      • FV ESXi Host Installation
      • FV VirtualBox Installation
    • System
      • Viewing the Dashboard
      • Accessing System and Device Information
      • Managing Topologies
      • Managing Devices
      • Viewing System Log
      • Managing Users
      • Performing Backup and Restore
      • Viewing Audit Logs
    • Configuration
      • Configuring Ports
      • Configuring Port Groups
      • Configuring Rule Templates
      • Configuring Vxlan Tunnel
      • Configuring Flows
      • Configuring VLAN
      • Configuring SNMP Trap
    • Statistics
      • Viewing Port Statistics
      • Viewing Flow Statistics
    • Help
  • REST API Guide
    • FLOW
    • Interface Management
    • Port Channel
    • LLDP
    • SNMP
    • System and Platform
    • Statistics
  • Use Cases
    • For Engineers
      • VxLAN Deployment (NVIDIA)
      • GTP Deployment
      • Truncation and Load Balancing
      • Ingress VLAN and Egress Tagging
      • Loopback-mode Port
      • VXLAN Stripping
      • VLAN Mode/Tag Actions
    • Command Reference
      • Converting Network-to-Tool port
      • Configuring 1G Electrical SFP
      • Enabling FlowVision On-box Support
  • Solution Integration
    • Network Visibility and Analysis with OPB, Arkime, Elasticsearch & Kibana
      • Installation Pre-Requisites
      • Solution Components
      • Configuring OPBNOS
      • Installing Arkime
      • Installing Kibana
      • Troubleshooting
  • Support
    • How to contact Aviz Networks Support?
Powered by GitBook
On this page

Was this helpful?

Export as PDF
  1. CLI Configuration Guide
  2. Display System Information

Show Environment

Use the following command to display information about your switches fan, power, and temperature:

pbnoscli# show environment 
tmp102-i2c-7-4a
Adapter: i2c-1-mux (chan_id 6)
Ambient Port Side Temp (air exhaust):  +36.4 C  (high = +160.0 C, hyst = +150.0 C)

mlxsw-i2c-2-48
Adapter: i2c-1-mux (chan_id 1)
Ambient ASIC Temp:  +53.0 C  (highest = +53.0 C)
front panel 001:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 002:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 003:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 004:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 005:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 006:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 007:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 008:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 009:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 010:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 011:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 012:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 013:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 014:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 015:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 016:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 017:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 018:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 019:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 020:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 021:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 022:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 023:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 024:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 025:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 026:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 027:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 028:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 029:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 030:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 031:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 032:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)

tps53679-i2c-5-71
Adapter: i2c-1-mux (chan_id 4)
PMIC-2 PSU 12V Rail (in1):        +11.95 V  (crit min =  +8.50 V, crit max = +15.00 V)
PMIC-2 PSU 12V Rail (in2):         +2.20 V  (crit min =  +1.80 V, crit max =  +2.80 V)
PMIC-2 ASIC 3.3V Rail (out):       +2.70 V  (crit min =  +2.10 V, crit max =  +3.60 V)
PMIC-2 Temp 1:                     +49.3 C  (high = +105.0 C, crit = +115.0 C)
PMIC-2 Temp 2:                     +49.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-2 ASIC 3.3V Rail Pwr (out):  218.75 mW (max = 450.00 W)
PMIC-2 ASIC 1.8V Rail Pwr (out):    0.00 W  
pout2:                             24.38 W  
PMIC-2 ASIC 3.3V Rail Curr (out):  +0.04 A  (max = +32.00 A, crit max = +40.00 A)
PMIC-2 ASIC 1.8V Rail Curr (out):  +0.00 A  (max = +64.00 A, crit max = +80.00 A)
iout2:                             +6.77 A  (max = +76.00 A, crit max = +95.00 A)

tps53679-i2c-15-58
Adapter: i2c-1-mux (chan_id 6)
PMIC-3 PSU 12V Rail (in1):          +12.03 V  (crit min =  +7.50 V, crit max = +17.00 V)
PMIC-3 PSU 12V Rail (in2):           +1.80 V  (crit min =  +1.25 V, crit max =  +2.40 V)
PMIC-3 COMEX 1.8V Rail (out):        +1.05 V  (crit min =  +0.65 V, crit max =  +1.55 V)
PMIC-3 Temp 1:                       +59.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-3 Temp 2:                       +59.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-3 COMEX 1.8V Rail Pwr (out):   110.11 mW (max = 450.00 W)
PMIC-3 COMEX 1.05V Rail Pwr (out):    5.38 W  
pout2:                                1.09 W  
PMIC-3 COMEX 1.8V Rail Curr (out):   +0.01 A  (max = +56.00 A, crit max = +63.50 A)
PMIC-3 COMEX 1.05V Rail Curr (out):  +1.34 A  (max = +55.00 A, crit max = +68.00 A)
iout2:                               +1.22 A  (max = +14.00 A, crit max = +17.00 A)

dps460-i2c-4-58
Adapter: i2c-1-mux (chan_id 3)
PSU-2 220V Rail (in):      +118.12 V  (crit min = +75.00 V, min = +80.00 V)
                                     (max = +280.00 V, crit max = +300.00 V)
PSU-2 12V Rail (out):      +12.04 V  (crit min =  +9.60 V, min = +10.80 V)
                                     (max = +13.80 V, crit max = +14.50 V)
PSU-2 Fan 1:               15840 RPM
PSU-2 Temp 1:               +26.8 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 2:               +34.0 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 3:               +33.0 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 220V Rail Pwr (in):  115.00 W  (max =   1.59 kW)
PSU-2 12V Rail Pwr (out):   90.75 W  (max =   1.19 kW, crit =   1.24 kW)
                                     (cap = -500.00 mW)
PSU-2 220V Rail Curr (in):  +0.98 A  (max = +17.62 A, crit max =  -0.50 A)
PSU-2 12V Rail Curr (out):  +7.40 A  (crit min =  -0.50 A, max = +99.00 A)
                                     (crit max = +103.50 A)

coretemp-isa-0000
Adapter: ISA adapter
Package id 0:  +59.0 C  (high = +82.0 C, crit = +104.0 C)
Core 0:        +59.0 C  (high = +82.0 C, crit = +104.0 C)
Core 1:        +59.0 C  (high = +82.0 C, crit = +104.0 C)

tmp102-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Ambient COMEX Temp:  +48.2 C  (high = +160.0 C, hyst = +150.0 C)

tmp102-i2c-7-49
Adapter: i2c-1-mux (chan_id 6)
Ambient Fan Side Temp (air intake):  +29.8 C  (high = +160.0 C, hyst = +150.0 C)

tps53679-i2c-15-61
Adapter: i2c-1-mux (chan_id 6)
PMIC-4 PSU 12V Rail (in1):         +12.02 V  (crit min =  +7.50 V, crit max = +17.00 V)
PMIC-4 PSU 12V Rail (in2):          +1.20 V  (crit min =  +0.80 V, crit max =  +1.90 V)
PMIC-4 COMEX 1.2V Rail (out):       +0.00 V  (crit min =  +0.00 V, crit max =  +1.55 V)
PMIC-4 Temp 1:                      +48.8 C  (high = +105.0 C, crit = +115.0 C)
PMIC-4 Temp 2:                      +48.8 C  (high = +105.0 C, crit = +115.0 C)
PMIC-4 COMEX 1.2V Rail Pwr (out):  330.08 mW (max = 450.00 W)
pout2:                               0.00 W  
PMIC-4 COMEX 1.2V Rail Curr (out):  +0.01 A  (max = +56.00 A, crit max = +63.50 A)
iout2:                              +0.00 A  (max = +18.00 A, crit max = +22.00 A)

tps53679-i2c-5-70
Adapter: i2c-1-mux (chan_id 4)
PMIC-1 PSU 12V Rail (in1):              +11.94 V  (crit min =  +8.50 V, crit max = +15.00 V)
PMIC-1 PSU 12V Rail (in2):               +0.80 V  (crit min =  +0.40 V, crit max =  +1.52 V)
PMIC-1 ASIC 0.8V VCORE Rail (out):       +1.20 V  (crit min =  +0.80 V, crit max =  +1.52 V)
PMIC-1 Temp 1:                           +51.2 C  (high = +105.0 C, crit = +115.0 C)
PMIC-1 Temp 2:                           +51.5 C  (high = +105.0 C, crit = +115.0 C)
PMIC-1 ASIC 0.8V VCORE Rail Pwr (out):  364.26 mW (max = 450.00 W)
PMIC-1 ASIC 1.2V Rail Pwr (out):         22.28 W  
pout2:                                   10.33 W  
PMIC-1 ASIC 0.8V VCORE Rail Curr (out):  +0.04 A  (max = +24.00 A, crit max = +32.00 A)
PMIC-1 ASIC 1.2V Rail Curr (out):        +4.27 A  (max = +250.00 A, crit max = +312.00 A)
iout2:                                   +8.61 A  (max = +35.00 A, crit max = +43.00 A)

mlxreg_fan-isa-0000
Adapter: ISA adapter
Chassis Fan Drawer-1 Tach 1: 5498 RPM
Chassis Fan Drawer-1 Tach 2: 4908 RPM
Chassis Fan Drawer-2 Tach 1: 5453 RPM
Chassis Fan Drawer-2 Tach 2: 4854 RPM
Chassis Fan Drawer-3 Tach 1: 5409 RPM
Chassis Fan Drawer-3 Tach 2: 4890 RPM
Chassis Fan Drawer-4 Tach 1: 5476 RPM
Chassis Fan Drawer-4 Tach 2: 4836 RPM

pbnoscli# 