Configuring SNMP Trap

Configure SNMP Trap

Traps are used when the Device needs to alert the Network Management software of an event without being polled. Traps ensure that the NMS gets information if a certain event occurs on the device that needs to be recorded without being polled by the NMS first. Managed network devices will have Trap MIBs with predefined conditions built into them. It’s crucial that the Network management system has these MIBs compiled into them to receive any traps sent by the given device/s. The primary focus of this feature is to support SNMP Trap notifications and in particular, linkUp, linkDown and config change trap notifications.

Supported MIBs
  • MIBS added to support SNMP Trap

  • DISMAN-EVENT-MIB.txt

  • INET-ADDRESS-MIB.txt

  • IPV6-TC.txt

With these MIBs, you can trigger sending an SNMP trap to a configured SNMP-server host based on certain events. Also, GET/GETNext/WALK operations can be supported on these mibs. The linkUp and linkDown traps are sent to the configured host in the event that an interface Admin or Oper status changes from up to down or vice-versa. The configChange trap monitors NPB (MAP, rule, port-npb config) and port (Speed, MTU, FEC, Autoneg) configuration changes. A configChangeTrap PDU is sent to the host when any value in these tables are modified, added or removed.

It's recommended not to set up more than 4 SNMP-Trap servers.

Reference

Example

You can verify the configuration by using the command(s) below:

Traps are only supported on SNMPv2c

Disable PSU/FAN traps:

Below commands can be used to disable FAN/PSU traps temporarily,

Reference

By default, traps are generated every 60 seconds, which may cause unnecessary stress on memory and CPU. To mitigate this, disabling the default behaviour using the above command is recommended for disabling PSU and FAN traps.

This will result in traps being generated only when the PSU/FAN state changes, reducing the load on memory and CPU.

SNMP Trap Logs:

SNMP-FRAMEWORK-MIB.txt

  • SNMPv2-SMI.txt

  • DISMAN-SCHEDULE-MIB.txt

  • IP-FORWARD-MIB.txt

  • IPV6-UDP-MIB.txt

  • SNMP-MPD-MIB.txt

  • SNMPv2-TC.txt

  • ENTITY-MIB.txt

  • IP-MIB.txt

  • MTA-MIB.txt

  • SNMP-NOTIFICATION-MIB.txt

  • SNMPv2-TM.txt

  • HOST-RESOURCES-MIB.txt

  • IPV6-ICMP-MIB.txt

  • NETWORK-SERVICES-MIB.txt

  • SNMP-TARGET-MIB.txt

  • SNMP-VIEW-BASED-ACM-MIB.txt

  • HOST-RESOURCES-TYPES.txt

  • IPV6-MIB.txt

  • NOTIFICATION-LOG-MIB.txt

  • SNMP-USER-BASED-SM-MIB.txt

  • TCP-MIB.txt

  • IF-MIB.txt

  • IPV6-TCP-MIB.txt

  • SNMP-COMMUNITY-MIB.txt

  • SNMPv2-MIB.txt

  • UDP-MIB.txt

  • Command

    [no] snmp-server trap modify <version><ip4addr|ip6addr> [port <value>] [community

    <value>]

    Description

    SNMP trap configuration

    Parameters

    Version, IPv4 or v6 Address , port, community values

    Mode

    CONFIG

    Command

    snmp-server trap (psu-util/fan-util) disable

    Description

    disable PSU/FAN traps temperoraly

    Parameters

    FAN/PSU

    Mode

    EXEC

    pbnoscli# configure terminal 
    pbnoscli(config)# snmp-server 
      community             Community string authentication
      contact               Configure SNMP contact
      location              Configure SNMP location
      trap                  Trap configuration
      user                  SNMP user
    pbnoscli(config)# snmp-server trap 
      cpu-util              CPU utilization
      disk-util             Disk utilization
      fan-util              FAN utilization
      mem-util              Memory utilization
      modify                Modify
      psu-util              PSU utilization
    pbnoscli(config)# snmp-server trap modify 
      <version>             Version value
    pbnoscli(config)# snmp-server trap modify 2 
      <ipaddr>              A.B.C.D
      <ip6addr>             A:B::C:D
      server-id             Server ID
    pbnoscli(config)# snmp-server trap modify 2tr server-id 1 
      <ipaddr>              A.B.C.D
      <ip6addr>             A:B::C:D
    pbnoscli(config)# snmp-server trap modify 2 server-id 1 10.2.2.11 port 29 community public
    pbnoscli(config)# 
    pbnoscli# show snmp-trap            
    =====================================================================================
    Host          Version       Dest IP         Dest Port    Community     Vrf         
    =====================================================================================
    1                2	   10.2.2.11         29             public     None      
    pbnoscli# 
    pbnoscli# configure terminal
    pbnoscli(config)# snmp
      snmp-server           SNMP server configuration
    pbnoscli(config)# snmp-server
      community             Community string authentication
      trap                  Trap configuration
    pbnoscli(config)# snmp-server trap
      cpu-util              CPU utilization
      disk-util             Disk utilization
      fan-util              FAN utilization
      mem-util              Memory utilization
      modify                Modify
      psu-util              PSU utilization
    pbnoscli(config)# snmp-server trap psu-util
      disable               Disable the PSU traps
    pbnoscli(config)# snmp-server trap psu-util 
      disable               Disable the PSU traps. Notify only on state change
    pbnoscli(config)# snmp-server trap psu-util disable
    pbnoscli(config)# snmp-server trap fan-util disable 
    pbnoscli(config)# end
    pbnoscli# 
    // As received on the SNMP server
    
    
    //Disk Traps
    10.4.5.244.47699 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.3="Current Disk usage 78% falls below threshold 79%" } }
    10.4.5.244.47549 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.2="Current Disk usage 88% raised above threshold 80%" } }
    10.4.5.244.47239 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.4="Disk /dev/sda3 failed" } }
    
    //CPU Traps
    10.4.5.244.49899 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.3="Current CPU usage 70% falling below threshold 80%" } }
    10.4.5.244.35699 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.2="Current CPU usage 88% raised above threshold 80%" } }
    
    //Memory Traps
    10.4.5.244.47689 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.3="Current mem usage 71% falling below threshold 80%" } }
    10.4.5.244.47656 > npbsrv01.snmp: [udp sum ok]  { SNMPv2c C="Aviz" { V2Trap(55) R=755944523  system.sysUpTime.0=5574 S:1.1.4.1.0=88.2.0.2="Current mem usage 88% raised above threshold 80%" } }
    
    //PSU Traps
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(101)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.1 E:58564.2.1.1.1="PSU 2 present, status OK"
    
    //FAN Traps
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan1 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan2 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan3 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan4 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan5 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan6 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan7 present, status OK"
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(100)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="fan8 present, status OK"
    
    10.4.4.52.32850 > npbsrv01.snmp:  V2Trap(105)  system.sysUpTime.0=42198 S:1.1.4.1.0=E:58564.2.1.1.2 E:58564.2.1.1.2="psu2_fan1 present, status OK"   
    pbnoscli# show running-config 
    configure terminal
    !
    interface mgmt
    ip address 10.4.4.52/24 gateway 10.4.4.1
    !
    snmp-server trap modify 2 server-id 1 10.2.2.11 port 29 community public
    snmp-server community public
    snmp-server trap fan-util disable
    snmp-server trap psu-util disable
    !
    pbnoscli# 
    https://support.aviznetworks.com/hc/en-us/articles/6940420122637-SNMP-Overview-and-Traps-Implemented-in-OPB-REL-2-1-0support.aviznetworks.com
    Aviz SNMP support