Interface Transceiver Information

To get information about the Interface transceiver, use the below commands:

pbnoscli# show interface transceiver presence
Port            Presence        
------------    -----------
Ethernet1/1     Present         
Ethernet2/1     Present         
Ethernet3/1     Present         
Ethernet4/1     Not present     
Ethernet5/1     Present         
Ethernet6/1     Present         
Ethernet7/1     Present         
Ethernet8/1     Not present     
Ethernet9/1     Not present     
Ethernet10/1    Not present     
Ethernet11/1    Not present     
Ethernet12/1    Not present     
Ethernet13/1    Present         
Ethernet14/1    Present         
<...>
Ethernet62/1    Not present     
Ethernet63/1    Present         
Ethernet64/1    Present         
pbnoscli# 
pbnoscli# show interface transceiver eeprom Ethernet1/1
Ethernet0: SFP EEPROM detected
        Application Advertisement: N/A
        Connector: CopperPigtail
        Encoding: Unspecified
        Extended Identifier: GBIC/SFP defined by twowire interface ID
        Extended RateSelect Compliance: Unspecified
        Identifier: SFP/SFP+/SFP28
        LengthOM3(UnitsOf10m): 0
        Nominal Bit Rate(100Mbs): 103
        Specification compliance:
                SFP+CableTechnology: Passive Cable
        Vendor Date Code(YYYY-MM-DD Lot): 2016-11-24 
        Vendor Name: Volex Inc.
        Vendor OUI: 14-1b-bd
        Vendor PN: 700512588
        Vendor Rev: A
        Vendor SN: 16CN48200200
pbnoscli#
pbnoscli# show interface transceiver lpmode Ethernet1/1
Port       Low-power Mode
---------  ----------------
Ethernet0  On

pbnoscli# show interface transceiver lpmode Ethernet3/1
Port       Low-power Mode
---------  ----------------
Ethernet8  Off
pbnoscli#

Show Platform Summary

Use the following command to display information about platform version:

pbnoscli# show platform summary  
 Platform: x86_64-mlnx_msn3700c-r0
 HwSKU: ACS-MSN3700C
 ASIC: mellanox
 ASIC Count: 1
 Serial Number: MT2043X14695
 Model Number: MSN3700-CS2FC
 Hardware Revision: A4
pbnoscli# 

Show platform pcieinfo

Use the following command to display information about pcie-info:

pbnoscli# show platform pcieinfo 
==============================Display PCIe Device===============================
bus:dev.fn 00:00.0 - dev_id=0x6f00, Host bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DMI2 (rev 03)
bus:dev.fn 00:01.0 - dev_id=0x6f02, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 03)
bus:dev.fn 00:01.1 - dev_id=0x6f03, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 03)
bus:dev.fn 00:02.0 - dev_id=0x6f04, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 03)
bus:dev.fn 00:02.2 - dev_id=0x6f06, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 03)
bus:dev.fn 00:03.0 - dev_id=0x6f08, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 03)
bus:dev.fn 00:03.2 - dev_id=0x6f0a, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 03)
bus:dev.fn 00:05.0 - dev_id=0x6f28, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management (rev 03)
bus:dev.fn 00:05.1 - dev_id=0x6f29, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug (rev 03)
bus:dev.fn 00:05.2 - dev_id=0x6f2a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors (rev 03)
bus:dev.fn 00:05.4 - dev_id=0x6f2c, PIC: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC (rev 03)
bus:dev.fn 00:14.0 - dev_id=0x8c31, USB controller: Intel Corporation 8 Series/C220 Series Chipset Family USB xHCI (rev 05)
bus:dev.fn 00:1c.0 - dev_id=0x8c10, PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #1 (rev d5)
bus:dev.fn 00:1c.7 - dev_id=0x8c1e, PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #8 (rev d5)
bus:dev.fn 00:1d.0 - dev_id=0x8c26, USB controller: Intel Corporation 8 Series/C220 Series Chipset Family USB EHCI #1 (rev 05)
bus:dev.fn 00:1f.0 - dev_id=0x8c54, ISA bridge: Intel Corporation C224 Series Chipset Family Server Standard SKU LPC Controller (rev 05)
bus:dev.fn 00:1f.2 - dev_id=0x8c02, SATA controller: Intel Corporation 8 Series/C220 Series Chipset Family 6-port SATA Controller 1 [AHCI mode] (rev 05)
bus:dev.fn 00:1f.3 - dev_id=0x8c22, SMBus: Intel Corporation 8 Series/C220 Series Chipset Family SMBus Controller (rev 05)
bus:dev.fn 03:00.0 - dev_id=0x6f50, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 0
bus:dev.fn 03:00.1 - dev_id=0x6f51, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 1
bus:dev.fn 03:00.2 - dev_id=0x6f52, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 2
bus:dev.fn 03:00.3 - dev_id=0x6f53, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 3
bus:dev.fn 06:00.0 - dev_id=0xcf6c, Ethernet controller: Mellanox Technologies MT53100 [Spectrum-2]
bus:dev.fn 08:00.0 - dev_id=0x1533, Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
bus:dev.fn ff:0b.0 - dev_id=0x6f81, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.1 - dev_id=0x6f36, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.2 - dev_id=0x6f37, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.3 - dev_id=0x6f76, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug (rev 03)
bus:dev.fn ff:0c.0 - dev_id=0x6fe0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0c.1 - dev_id=0x6fe1, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.0 - dev_id=0x6ff8, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.4 - dev_id=0x6ffc, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.5 - dev_id=0x6ffd, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.6 - dev_id=0x6ffe, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:10.0 - dev_id=0x6f1d, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 03)
bus:dev.fn ff:10.1 - dev_id=0x6f34, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 03)
bus:dev.fn ff:10.5 - dev_id=0x6f1e, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:10.6 - dev_id=0x6f7d, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:10.7 - dev_id=0x6f1f, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:12.0 - dev_id=0x6fa0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 03)
bus:dev.fn ff:12.1 - dev_id=0x6f30, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 03)
bus:dev.fn ff:13.0 - dev_id=0x6fa8, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 03)
bus:dev.fn ff:13.1 - dev_id=0x6f71, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 03)
bus:dev.fn ff:13.2 - dev_id=0x6faa, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.3 - dev_id=0x6fab, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.4 - dev_id=0x6fac, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.5 - dev_id=0x6fad, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.6 - dev_id=0x6fae, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast (rev 03)
bus:dev.fn ff:13.7 - dev_id=0x6faf, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 03)
bus:dev.fn ff:14.0 - dev_id=0x6fb0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control (rev 03)
bus:dev.fn ff:14.1 - dev_id=0x6fb1, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control (rev 03)
bus:dev.fn ff:14.2 - dev_id=0x6fb2, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error (rev 03)
bus:dev.fn ff:14.3 - dev_id=0x6fb3, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error (rev 03)
bus:dev.fn ff:14.4 - dev_id=0x6fbc, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.5 - dev_id=0x6fbd, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.6 - dev_id=0x6fbe, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.7 - dev_id=0x6fbf, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:15.0 - dev_id=0x6fb4, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control (rev 03)
bus:dev.fn ff:15.1 - dev_id=0x6fb5, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control (rev 03)
bus:dev.fn ff:15.2 - dev_id=0x6fb6, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error (rev 03)
bus:dev.fn ff:15.3 - dev_id=0x6fb7, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error (rev 03)
bus:dev.fn ff:1e.0 - dev_id=0x6f98, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.1 - dev_id=0x6f99, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.2 - dev_id=0x6f9a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.3 - dev_id=0x6fc0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.4 - dev_id=0x6f9c, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1f.0 - dev_id=0x6f88, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1f.2 - dev_id=0x6f8a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
pbnoscli# 

Show Platform Syseeprom

Use the following command to display information about syseeprom:

pbnoscli# show platform syseeprom 
TlvInfo Header:
	Id String:	TlvInfo
	Version:	1
	Total Length:	629

==========================================================================
        TLV Name            Code             LEN                   VALUE
==========================================================================
  Device Version            0x26               1                       1
    Product Name            0x21              64                MSN3700C
Vendor Extension            0xfd              36                        
Vendor Extension            0xfd             164                        
Vendor Extension            0xfd              36                        
Vendor Extension            0xfd              36                        
Vendor Extension            0xfd              36                        
Vendor Extension            0xfd              52                        
Manufacture Date            0x25              19     10/25/2020 20:33:38
    ONIE Version            0x29              23 2019.11-5.2.0020-115200
Base MAC Address            0x24               6       1C:34:DA:24:DE:00
          CRC-32            0xfe               4              0xA358E6B0
     Part Number            0x22              20           MSN3700-CS2FC
    Manufacturer            0x2b               8                Mellanox
   Platform Name            0x28              64 x86_64-mlnx_msn3700C-r0
   Serial Number            0x23              24            MT2043X14695
   MAC Addresses            0x2a               2                     254
pbnoscli# 

Show Environment

Use the following command to display information about your switches fan, power, and temperature:

System Uptime

To check system uptime, use the below command:

pbnoscli# show uptime 
 08:33:19 up 1 day, 21:52, 16 users,  load average: 1.35, 1.30, 1.29
pbnoscli# 
pbnoscli# show environment 
tmp102-i2c-7-4a
Adapter: i2c-1-mux (chan_id 6)
Ambient Port Side Temp (air exhaust):  +36.4 C  (high = +160.0 C, hyst = +150.0 C)

mlxsw-i2c-2-48
Adapter: i2c-1-mux (chan_id 1)
Ambient ASIC Temp:  +53.0 C  (highest = +53.0 C)
front panel 001:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 002:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 003:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 004:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 005:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 006:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 007:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 008:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 009:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 010:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 011:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 012:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 013:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 014:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 015:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 016:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 017:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 018:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 019:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 020:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 021:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 022:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 023:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 024:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 025:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 026:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 027:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 028:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 029:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 030:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 031:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)
front panel 032:     +0.0 C  (crit =  +0.0 C, emerg =  +0.0 C)

tps53679-i2c-5-71
Adapter: i2c-1-mux (chan_id 4)
PMIC-2 PSU 12V Rail (in1):        +11.95 V  (crit min =  +8.50 V, crit max = +15.00 V)
PMIC-2 PSU 12V Rail (in2):         +2.20 V  (crit min =  +1.80 V, crit max =  +2.80 V)
PMIC-2 ASIC 3.3V Rail (out):       +2.70 V  (crit min =  +2.10 V, crit max =  +3.60 V)
PMIC-2 Temp 1:                     +49.3 C  (high = +105.0 C, crit = +115.0 C)
PMIC-2 Temp 2:                     +49.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-2 ASIC 3.3V Rail Pwr (out):  218.75 mW (max = 450.00 W)
PMIC-2 ASIC 1.8V Rail Pwr (out):    0.00 W  
pout2:                             24.38 W  
PMIC-2 ASIC 3.3V Rail Curr (out):  +0.04 A  (max = +32.00 A, crit max = +40.00 A)
PMIC-2 ASIC 1.8V Rail Curr (out):  +0.00 A  (max = +64.00 A, crit max = +80.00 A)
iout2:                             +6.77 A  (max = +76.00 A, crit max = +95.00 A)

tps53679-i2c-15-58
Adapter: i2c-1-mux (chan_id 6)
PMIC-3 PSU 12V Rail (in1):          +12.03 V  (crit min =  +7.50 V, crit max = +17.00 V)
PMIC-3 PSU 12V Rail (in2):           +1.80 V  (crit min =  +1.25 V, crit max =  +2.40 V)
PMIC-3 COMEX 1.8V Rail (out):        +1.05 V  (crit min =  +0.65 V, crit max =  +1.55 V)
PMIC-3 Temp 1:                       +59.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-3 Temp 2:                       +59.1 C  (high = +105.0 C, crit = +115.0 C)
PMIC-3 COMEX 1.8V Rail Pwr (out):   110.11 mW (max = 450.00 W)
PMIC-3 COMEX 1.05V Rail Pwr (out):    5.38 W  
pout2:                                1.09 W  
PMIC-3 COMEX 1.8V Rail Curr (out):   +0.01 A  (max = +56.00 A, crit max = +63.50 A)
PMIC-3 COMEX 1.05V Rail Curr (out):  +1.34 A  (max = +55.00 A, crit max = +68.00 A)
iout2:                               +1.22 A  (max = +14.00 A, crit max = +17.00 A)

dps460-i2c-4-58
Adapter: i2c-1-mux (chan_id 3)
PSU-2 220V Rail (in):      +118.12 V  (crit min = +75.00 V, min = +80.00 V)
                                     (max = +280.00 V, crit max = +300.00 V)
PSU-2 12V Rail (out):      +12.04 V  (crit min =  +9.60 V, min = +10.80 V)
                                     (max = +13.80 V, crit max = +14.50 V)
PSU-2 Fan 1:               15840 RPM
PSU-2 Temp 1:               +26.8 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 2:               +34.0 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 3:               +33.0 C  (low  =  -0.5 C, high = +60.0 C)
                                     (crit low = -20.0 C, crit = +65.0 C)
PSU-2 220V Rail Pwr (in):  115.00 W  (max =   1.59 kW)
PSU-2 12V Rail Pwr (out):   90.75 W  (max =   1.19 kW, crit =   1.24 kW)
                                     (cap = -500.00 mW)
PSU-2 220V Rail Curr (in):  +0.98 A  (max = +17.62 A, crit max =  -0.50 A)
PSU-2 12V Rail Curr (out):  +7.40 A  (crit min =  -0.50 A, max = +99.00 A)
                                     (crit max = +103.50 A)

coretemp-isa-0000
Adapter: ISA adapter
Package id 0:  +59.0 C  (high = +82.0 C, crit = +104.0 C)
Core 0:        +59.0 C  (high = +82.0 C, crit = +104.0 C)
Core 1:        +59.0 C  (high = +82.0 C, crit = +104.0 C)

tmp102-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Ambient COMEX Temp:  +48.2 C  (high = +160.0 C, hyst = +150.0 C)

tmp102-i2c-7-49
Adapter: i2c-1-mux (chan_id 6)
Ambient Fan Side Temp (air intake):  +29.8 C  (high = +160.0 C, hyst = +150.0 C)

tps53679-i2c-15-61
Adapter: i2c-1-mux (chan_id 6)
PMIC-4 PSU 12V Rail (in1):         +12.02 V  (crit min =  +7.50 V, crit max = +17.00 V)
PMIC-4 PSU 12V Rail (in2):          +1.20 V  (crit min =  +0.80 V, crit max =  +1.90 V)
PMIC-4 COMEX 1.2V Rail (out):       +0.00 V  (crit min =  +0.00 V, crit max =  +1.55 V)
PMIC-4 Temp 1:                      +48.8 C  (high = +105.0 C, crit = +115.0 C)
PMIC-4 Temp 2:                      +48.8 C  (high = +105.0 C, crit = +115.0 C)
PMIC-4 COMEX 1.2V Rail Pwr (out):  330.08 mW (max = 450.00 W)
pout2:                               0.00 W  
PMIC-4 COMEX 1.2V Rail Curr (out):  +0.01 A  (max = +56.00 A, crit max = +63.50 A)
iout2:                              +0.00 A  (max = +18.00 A, crit max = +22.00 A)

tps53679-i2c-5-70
Adapter: i2c-1-mux (chan_id 4)
PMIC-1 PSU 12V Rail (in1):              +11.94 V  (crit min =  +8.50 V, crit max = +15.00 V)
PMIC-1 PSU 12V Rail (in2):               +0.80 V  (crit min =  +0.40 V, crit max =  +1.52 V)
PMIC-1 ASIC 0.8V VCORE Rail (out):       +1.20 V  (crit min =  +0.80 V, crit max =  +1.52 V)
PMIC-1 Temp 1:                           +51.2 C  (high = +105.0 C, crit = +115.0 C)
PMIC-1 Temp 2:                           +51.5 C  (high = +105.0 C, crit = +115.0 C)
PMIC-1 ASIC 0.8V VCORE Rail Pwr (out):  364.26 mW (max = 450.00 W)
PMIC-1 ASIC 1.2V Rail Pwr (out):         22.28 W  
pout2:                                   10.33 W  
PMIC-1 ASIC 0.8V VCORE Rail Curr (out):  +0.04 A  (max = +24.00 A, crit max = +32.00 A)
PMIC-1 ASIC 1.2V Rail Curr (out):        +4.27 A  (max = +250.00 A, crit max = +312.00 A)
iout2:                                   +8.61 A  (max = +35.00 A, crit max = +43.00 A)

mlxreg_fan-isa-0000
Adapter: ISA adapter
Chassis Fan Drawer-1 Tach 1: 5498 RPM
Chassis Fan Drawer-1 Tach 2: 4908 RPM
Chassis Fan Drawer-2 Tach 1: 5453 RPM
Chassis Fan Drawer-2 Tach 2: 4854 RPM
Chassis Fan Drawer-3 Tach 1: 5409 RPM
Chassis Fan Drawer-3 Tach 2: 4890 RPM
Chassis Fan Drawer-4 Tach 1: 5476 RPM
Chassis Fan Drawer-4 Tach 2: 4836 RPM

pbnoscli# 

Reboot Cause

Use the following command to display information about system-reboot:

pbnoscli# show reboot-cause
Hardware - Other (Reset caused by hotswap or halt)
pbnoscli# 

pbnoscli# show reboot-cause 
User issued 'reboot' command [User: admin, Time: Tue 02 Aug 2022 03:01:03 AM UTC]
pbnoscli# 

Display System Information

APB provides various commands to display various types of platform information as follows:

  • System Hardware Information

  • System Services Information

Interface Information

Show Platform SSD

Use the following command to display information about device SSD:

pbnoscli# show platform ssdhealth 
Device Model : StorFly VSFBM4XC030G-MLX1
Health       : 99.395%
Temperature  : 47C
pbnoscli#

Show Platform PSU

Use the following command to display information about device PSU:

pbnoscli# show platform psustatus 
============================================================================================================================================
   PSU           Model          Serial   Hardware Revision     Voltage (V)     Current (A)       Power (W)      Status             LED
============================================================================================================================================
 PSU 1             N/A             N/A             N/A             N/A             N/A             N/A          NOT OK             red
 PSU 2   MTEF-PSF-AC-C    MT2042X11384              A3          12.035           7.273            88.5              OK             red
pbnoscli# 

Show System Memory

You can display information about system memory information using the following command:

pbnoscli# show system memory
               total        used        free      shared  buff/cache   available
Mem:           7.7Gi       3.5Gi       2.6Gi       154Mi       1.6Gi       3.7Gi
Swap:             0B          0B          0B

Show Services

Use the following command to display information about running services on the device:

pbnoscli# show services 
lldp	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.3  30388 24176 pts/0    Ss+  08:09   0:02 /usr/bin/python3 /usr/local/bin/supervisord
root          12  0.0  0.2  25616 19104 pts/0    S    08:09   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name lldp
root          15  0.0  0.0 223808  5616 pts/0    Sl   08:09   0:00 /usr/sbin/rsyslogd -n -iNONE
_lldpd        23  0.0  0.0  28364  7692 pts/0    S    08:09   0:00 lldpd: monitor. 
_lldpd        25  0.0  0.0  28612  3820 pts/0    S    08:09   0:01 lldpd: 2 neighbors.
root          32  0.0  0.2 105268 21700 pts/0    Sl   08:09   0:03 python3 -m lldp_syncd
root          36  0.0  0.2  34608 22280 pts/0    S    08:09   0:00 python3 /usr/bin/lldpmgrd

snmp	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.3  33644 24436 pts/0    Ss+  08:12   0:01 /usr/bin/python3 /usr/local/bin/supervisord
root          10  0.0  0.2  31100 19440 pts/0    S    08:12   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name snmp
root          18  0.0  0.0 223808  5616 pts/0    Sl   08:12   0:00 /usr/sbin/rsyslogd -n -iNONE
Debian-+      22  0.9  0.2  37484 19024 pts/0    S    08:12   0:35 /usr/sbin/snmpd -f -LS4d -Lf /var/log/snmpd.log -u Debian-snmp -g Debian-snmp -I -smux -p /run/snmpd.pid
root          23  4.0  0.4 348084 36636 pts/0    Sl   08:12   2:34 python3 -m sonic_ax_impl

pmon	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.3  30700 24312 pts/0    Ss+  08:08   0:02 /usr/bin/python3 /usr/local/bin/supervisord
root          47  0.0  0.2  25636 19068 pts/0    S    08:08   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name pmon
root          50  0.0  0.0 223808  3632 pts/0    Sl   08:08   0:00 /usr/sbin/rsyslogd -n -iNONE
root          56  0.3  1.0 213980 86084 pts/0    Sl   08:08   0:13 python3 /usr/local/bin/xcvrd
root          58  0.3  1.0 137540 82448 pts/0    S    08:08   0:13 python3 /usr/local/bin/psud
root          60  0.0  1.0 138596 83760 pts/0    S    08:08   0:00 python3 /usr/local/bin/syseepromd
root          61  0.2  1.0 138960 84516 pts/0    S    08:08   0:10 python3 /usr/local/bin/thermalctld
root          63  0.1  1.0 138840 84440 pts/0    S    08:08   0:06 python3 /usr/local/bin/pcied
root          64  0.1  0.7 138960 64100 pts/0    S    08:08   0:05 python3 /usr/local/bin/thermalctld
root          70  0.0  0.0  59092  1076 ?        Ss   08:08   0:00 /usr/sbin/sensord -f daemon
root         408  0.0  0.8 214556 71224 pts/0    S    08:09   0:00 python3 /usr/local/bin/xcvrd

sflow	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.2  30256 23992 pts/0    Ss+  08:08   0:01 /usr/bin/python3 /usr/local/bin/supervisord
root          10  0.0  0.2  25612 19032 pts/0    S    08:08   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name sflow
root          13  0.0  0.0 223808  5424 pts/0    Sl   08:08   0:00 /usr/sbin/rsyslogd -n -iNONE
root          17  0.0  0.1  88328  8124 pts/0    Sl   08:08   0:00 /usr/bin/sflowmgrd
root          18  0.0  0.2  30752 20532 pts/0    S    08:08   0:00 python3 /usr/bin/port_index_mapper.py

nagr	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.2  59008 21160 pts/0    Ss+  08:08   0:02 /usr/bin/python /usr/local/bin/supervisord
root          10  4.9  1.2 486580 103668 pts/0   Sl   08:08   3:22 /usr/bin/python3 /gemini/NTPRest/naggc.py
root          11  0.0  0.2  60380 18508 pts/0    S    08:08   0:00 /usr/bin/python3 /usr/bin/lag.py
root          12  0.0  0.2  60360 18652 pts/0    S    08:08   0:00 /usr/bin/python3 /usr/bin/netlink_route.py
root          13  0.0  0.2 206576 17192 pts/0    Sl   08:08   0:00 /usr/bin/python3 /usr/bin/toolhc.py
root          14  0.0  0.2  60356 18240 pts/0    S    08:08   0:00 /usr/bin/python3 /usr/bin/netlink_poll.py
root          21  0.0  0.0 262992  3420 pts/0    Sl   08:08   0:00 /usr/sbin/rsyslogd -n

syncd	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.3  30568 24232 pts/0    Ss+  08:08   0:01 /usr/bin/python3 /usr/local/bin/supervisord
root          10  0.0  0.2  25704 19316 pts/0    S    08:08   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name syncd
root          14  0.0  0.0 223808  5576 pts/0    Sl   08:08   0:00 /usr/sbin/rsyslogd -n -iNONE
root          19  1.7  1.5 1784640 128056 pts/0  Sl   08:08   1:09 /usr/bin/syncd -u -s -p /tmp/sai.profile
root          44  5.6 11.1 1365284 895996 pts/0  Sl   08:08   3:49 sx_sdk --logger libsai.so
root          66  0.0  1.9 343036 155164 pts/0   Sl   08:08   0:01 /usr/bin/python3 /usr/bin/mellanox_nagg_asic.py

swss	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.1  0.3  30652 24500 pts/0    Ss+  08:07   0:05 /usr/bin/python3 /usr/local/bin/supervisord
root          26  0.0  0.2  25620 19040 pts/0    S    08:07   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name swss
root          29  0.0  0.0 223808  3596 pts/0    Sl   08:07   0:00 /usr/sbin/rsyslogd -n -iNONE
root          34  0.0  0.0  81260  4960 pts/0    Sl   08:07   0:00 /usr/bin/portsyncd
root          39  0.0  0.2 403316 22456 pts/0    Sl   08:08   0:03 /usr/bin/orchagent -d /var/log/swss -b 8192 -s
root          64  0.0  0.1  88384  8176 pts/0    Sl   08:08   0:00 /usr/bin/coppmgrd
root          76  0.0  0.0   3964  2928 pts/0    S    08:08   0:00 /bin/bash /usr/bin/arp_update
root          77  0.0  0.0  81132  4404 pts/0    Sl   08:08   0:00 /usr/bin/neighsyncd
root          79  0.0  0.1  88448  8548 pts/0    Sl   08:08   0:00 /usr/bin/vlanmgrd
root          81  0.0  0.1  88472  8564 pts/0    Sl   08:08   0:00 /usr/bin/intfmgrd
root          83  0.0  0.1  88412  8332 pts/0    Sl   08:08   0:00 /usr/bin/portmgrd
root          85  0.0  0.1  88508 10240 pts/0    Sl   08:08   0:00 /usr/bin/buffermgrd -l /usr/share/sonic/hwsku/pg_profile_lookup.ini
root          98  0.0  0.1  88444  8420 pts/0    Sl   08:08   0:00 /usr/bin/vrfmgrd
root         104  0.0  0.1  88344  8248 pts/0    Sl   08:08   0:00 /usr/bin/nbrmgrd
root         112  0.0  0.1  88472  8332 pts/0    Sl   08:08   0:00 /usr/bin/vxlanmgrd
root         117  0.0  0.0  81176  4796 pts/0    Sl   08:08   0:00 /usr/bin/fdbsyncd
root         122  0.0  0.1  88416  8244 pts/0    Sl   08:08   0:00 /usr/bin/tunnelmgrd
root         153  0.0  0.0   5668  1684 pts/0    S    08:08   0:00 /usr/sbin/ndppd
root        6652  0.0  0.0   2524   744 pts/0    S    09:13   0:00 sleep 300

database	docker
---------------------------
USER         PID %CPU %MEM    VSZ   RSS TTY      STAT START   TIME COMMAND
root           1  0.0  0.2  30248 23700 pts/0    Ss+  08:07   0:01 /usr/bin/python3 /usr/local/bin/supervisord
root          38  0.0  0.2  25612 19032 pts/0    S    08:07   0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name database
root          39  0.0  0.0 223808  5616 pts/0    Sl   08:07   0:00 /usr/sbin/rsyslogd -n -iNONE
root          40  4.0  0.7 110832 59672 pts/0    Sl   08:07   2:46 /usr/bin/redis-server 127.0.0.1:6379

pbnoscli# 

Show Docker Memory

You can display information about docker memory-usage use the following command:

pbnoscli# show docker memory-usage 
pbnoscli# show docker memory-usage 
CONTAINER ID   NAME       CPU %     MEM USAGE / LIMIT     MEM %     NET I/O   BLOCK I/O         PIDS
65f6de2cc45d   lldp       0.05%     55.61MiB / 7.669GiB   0.71%     0B / 0B   7.32MB / 127kB    11
6113df8cd655   snmp       5.80%     91.01MiB / 7.669GiB   1.16%     0B / 0B   57.3kB / 98.3kB   10
a6770092098b   pmon       20.78%    378.7MiB / 7.669GiB   4.82%     0B / 0B   89.4MB / 139kB    17
29fac3d30c6c   sflow      0.04%     39.71MiB / 7.669GiB   0.51%     0B / 0B   2.7MB / 69.6kB    9
a1ba99baa6bb   nagr       48.85%    278.2MiB / 7.669GiB   3.54%     0B / 0B   47.8MB / 139kB    15
c1b2207591a6   syncd      2.23%     1.204GiB / 7.669GiB   15.70%    0B / 0B   110MB / 34.8MB    48
96d750ff6689   swss       0.14%     64.02MiB / 7.669GiB   0.82%     0B / 0B   22.9MB / 270kB    40
2c4c2b3c37cc   database   5.71%     113.8MiB / 7.669GiB   1.45%     0B / 0B   42.3MB / 65.5kB   11
pbnoscli#

Show Platform Fan

Use the following command to display information about system fans:

pbnoscli# show platform fan 
=====================================================================================================================================
ID    DRAWER             FAN          SPEED%       DIRECTION        PRESENCE          STATUS             LED          TIME STAMP
=====================================================================================================================================
 1   drawer1            fan1              21          intake            True              OK           green      20220926 09:17:26
 2   drawer1            fan2              19          intake            True              OK           green      20220926 09:17:26
 3   drawer2            fan3              21          intake            True              OK           green      20220926 09:17:26
 4   drawer2            fan4              19          intake            True              OK           green      20220926 09:17:26
 5   drawer3            fan5              21          intake            True              OK           green      20220926 09:17:26
 6   drawer3            fan6              19          intake            True              OK           green      20220926 09:17:26
 7   drawer4            fan7              21          intake            True              OK           green      20220926 09:17:26
 8   drawer4            fan8              18          intake            True              OK           green      20220926 09:17:26
 9       N/A       psu1_fan1             N/A             N/A             N/A              N/A            N/A      20220926 09:17:26
10       N/A       psu2_fan1              63             N/A            True              OK             red      20220926 09:17:26
pbnoscli# 

Show Platform Temperature

Use the following command to display information about device temperature sensors:

pbnoscli# show platform temperature 
=============================================================================================================================================
                Sensor   Temperature       Warning       High TH        Low TH    Critical High TH     Critical Low TH             Timestamp
=============================================================================================================================================
    xSFP module 3 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
    xSFP module 7 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 27 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
       CPU Core 0 Temp          58.0         False          82.0           N/A               104.0                 N/A     20220926 09:22:26
    xSFP module 9 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 14 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 19 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 23 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
   xSFP module 30 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
   xSFP module 15 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
                  ASIC          53.0         False         105.0           N/A               120.0                 N/A     20220926 09:22:26
       CPU Core 1 Temp          59.0         False          82.0           N/A               104.0                 N/A     20220926 09:22:26
 Ambient Fan Side Temp        29.812         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
    xSFP module 4 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 26 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
   xSFP module 12 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
    xSFP module 5 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
            PSU-2 Temp         26.75         False          60.0           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 24 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
         CPU Pack Temp          59.0         False          82.0           N/A               104.0                 N/A     20220926 09:22:26
   xSFP module 10 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
Ambient Port Side Temp        36.437         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 17 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
    xSFP module 1 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 21 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 31 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
   xSFP module 11 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
            PSU-1 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
    xSFP module 8 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 18 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 29 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
   xSFP module 32 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
    Ambient COMEX Temp        48.125         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 28 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
    xSFP module 2 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 20 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 16 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 13 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 25 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
    xSFP module 6 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:26
   xSFP module 22 Temp           N/A         False           N/A           N/A                 N/A                 N/A     20220926 09:22:27
pbnoscli#