Use the following command to display information about platform version:
pbnoscli# show platform summary
Platform: x86_64-mlnx_msn3700c-r0
HwSKU: ACS-MSN3700C
ASIC: mellanox
ASIC Count: 1
Serial Number: MT2043X14695
Model Number: MSN3700-CS2FC
Hardware Revision: A4
pbnoscli#
Use the following command to display information about syseeprom:
pbnoscli# show platform syseeprom
TlvInfo Header:
Id String: TlvInfo
Version: 1
Total Length: 629
==========================================================================
TLV Name Code LEN VALUE
==========================================================================
Device Version 0x26 1 1
Product Name 0x21 64 MSN3700C
Vendor Extension 0xfd 36
Vendor Extension 0xfd 164
Vendor Extension 0xfd 36
Vendor Extension 0xfd 36
Vendor Extension 0xfd 36
Vendor Extension 0xfd 52
Manufacture Date 0x25 19 10/25/2020 20:33:38
ONIE Version 0x29 23 2019.11-5.2.0020-115200
Base MAC Address 0x24 6 1C:34:DA:24:DE:00
CRC-32 0xfe 4 0xA358E6B0
Part Number 0x22 20 MSN3700-CS2FC
Manufacturer 0x2b 8 Mellanox
Platform Name 0x28 64 x86_64-mlnx_msn3700C-r0
Serial Number 0x23 24 MT2043X14695
MAC Addresses 0x2a 2 254
pbnoscli#
OPBNOS provides various commands to display various types of platform information as follows:
System Hardware Information
System Services Information
Interface Information
To get information about the Interface transceiver, use the below commands:
pbnoscli# show interface transceiver presence
Port Presence
------------ -----------
Ethernet1/1 Present
Ethernet2/1 Present
Ethernet3/1 Present
Ethernet4/1 Not present
Ethernet5/1 Present
Ethernet6/1 Present
Ethernet7/1 Present
Ethernet8/1 Not present
Ethernet9/1 Not present
Ethernet10/1 Not present
Ethernet11/1 Not present
Ethernet12/1 Not present
Ethernet13/1 Present
Ethernet14/1 Present
<...>
Ethernet62/1 Not present
Ethernet63/1 Present
Ethernet64/1 Present
pbnoscli#
pbnoscli# show interface transceiver eeprom Ethernet1/1
Ethernet0: SFP EEPROM detected
Application Advertisement: N/A
Connector: CopperPigtail
Encoding: Unspecified
Extended Identifier: GBIC/SFP defined by twowire interface ID
Extended RateSelect Compliance: Unspecified
Identifier: SFP/SFP+/SFP28
LengthOM3(UnitsOf10m): 0
Nominal Bit Rate(100Mbs): 103
Specification compliance:
SFP+CableTechnology: Passive Cable
Vendor Date Code(YYYY-MM-DD Lot): 2016-11-24
Vendor Name: Volex Inc.
Vendor OUI: 14-1b-bd
Vendor PN: 700512588
Vendor Rev: A
Vendor SN: 16CN48200200
pbnoscli#
pbnoscli# show interface transceiver lpmode Ethernet1/1
Port Low-power Mode
--------- ----------------
Ethernet0 On
pbnoscli# show interface transceiver lpmode Ethernet3/1
Port Low-power Mode
--------- ----------------
Ethernet8 Off
pbnoscli#
To check system uptime, use the below command:
pbnoscli# show uptime
08:33:19 up 1 day, 21:52, 16 users, load average: 1.35, 1.30, 1.29
pbnoscli#
Use the following command to display information about your switches fan, power, and temperature:
pbnoscli# show environment
tmp102-i2c-7-4a
Adapter: i2c-1-mux (chan_id 6)
Ambient Port Side Temp (air exhaust): +36.4 C (high = +160.0 C, hyst = +150.0 C)
mlxsw-i2c-2-48
Adapter: i2c-1-mux (chan_id 1)
Ambient ASIC Temp: +53.0 C (highest = +53.0 C)
front panel 001: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 002: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 003: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 004: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 005: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 006: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 007: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 008: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 009: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 010: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 011: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 012: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 013: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 014: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 015: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 016: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 017: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 018: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 019: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 020: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 021: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 022: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 023: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 024: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 025: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 026: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 027: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 028: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 029: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 030: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 031: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
front panel 032: +0.0 C (crit = +0.0 C, emerg = +0.0 C)
tps53679-i2c-5-71
Adapter: i2c-1-mux (chan_id 4)
PMIC-2 PSU 12V Rail (in1): +11.95 V (crit min = +8.50 V, crit max = +15.00 V)
PMIC-2 PSU 12V Rail (in2): +2.20 V (crit min = +1.80 V, crit max = +2.80 V)
PMIC-2 ASIC 3.3V Rail (out): +2.70 V (crit min = +2.10 V, crit max = +3.60 V)
PMIC-2 Temp 1: +49.3 C (high = +105.0 C, crit = +115.0 C)
PMIC-2 Temp 2: +49.1 C (high = +105.0 C, crit = +115.0 C)
PMIC-2 ASIC 3.3V Rail Pwr (out): 218.75 mW (max = 450.00 W)
PMIC-2 ASIC 1.8V Rail Pwr (out): 0.00 W
pout2: 24.38 W
PMIC-2 ASIC 3.3V Rail Curr (out): +0.04 A (max = +32.00 A, crit max = +40.00 A)
PMIC-2 ASIC 1.8V Rail Curr (out): +0.00 A (max = +64.00 A, crit max = +80.00 A)
iout2: +6.77 A (max = +76.00 A, crit max = +95.00 A)
tps53679-i2c-15-58
Adapter: i2c-1-mux (chan_id 6)
PMIC-3 PSU 12V Rail (in1): +12.03 V (crit min = +7.50 V, crit max = +17.00 V)
PMIC-3 PSU 12V Rail (in2): +1.80 V (crit min = +1.25 V, crit max = +2.40 V)
PMIC-3 COMEX 1.8V Rail (out): +1.05 V (crit min = +0.65 V, crit max = +1.55 V)
PMIC-3 Temp 1: +59.1 C (high = +105.0 C, crit = +115.0 C)
PMIC-3 Temp 2: +59.1 C (high = +105.0 C, crit = +115.0 C)
PMIC-3 COMEX 1.8V Rail Pwr (out): 110.11 mW (max = 450.00 W)
PMIC-3 COMEX 1.05V Rail Pwr (out): 5.38 W
pout2: 1.09 W
PMIC-3 COMEX 1.8V Rail Curr (out): +0.01 A (max = +56.00 A, crit max = +63.50 A)
PMIC-3 COMEX 1.05V Rail Curr (out): +1.34 A (max = +55.00 A, crit max = +68.00 A)
iout2: +1.22 A (max = +14.00 A, crit max = +17.00 A)
dps460-i2c-4-58
Adapter: i2c-1-mux (chan_id 3)
PSU-2 220V Rail (in): +118.12 V (crit min = +75.00 V, min = +80.00 V)
(max = +280.00 V, crit max = +300.00 V)
PSU-2 12V Rail (out): +12.04 V (crit min = +9.60 V, min = +10.80 V)
(max = +13.80 V, crit max = +14.50 V)
PSU-2 Fan 1: 15840 RPM
PSU-2 Temp 1: +26.8 C (low = -0.5 C, high = +60.0 C)
(crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 2: +34.0 C (low = -0.5 C, high = +60.0 C)
(crit low = -20.0 C, crit = +65.0 C)
PSU-2 Temp 3: +33.0 C (low = -0.5 C, high = +60.0 C)
(crit low = -20.0 C, crit = +65.0 C)
PSU-2 220V Rail Pwr (in): 115.00 W (max = 1.59 kW)
PSU-2 12V Rail Pwr (out): 90.75 W (max = 1.19 kW, crit = 1.24 kW)
(cap = -500.00 mW)
PSU-2 220V Rail Curr (in): +0.98 A (max = +17.62 A, crit max = -0.50 A)
PSU-2 12V Rail Curr (out): +7.40 A (crit min = -0.50 A, max = +99.00 A)
(crit max = +103.50 A)
coretemp-isa-0000
Adapter: ISA adapter
Package id 0: +59.0 C (high = +82.0 C, crit = +104.0 C)
Core 0: +59.0 C (high = +82.0 C, crit = +104.0 C)
Core 1: +59.0 C (high = +82.0 C, crit = +104.0 C)
tmp102-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Ambient COMEX Temp: +48.2 C (high = +160.0 C, hyst = +150.0 C)
tmp102-i2c-7-49
Adapter: i2c-1-mux (chan_id 6)
Ambient Fan Side Temp (air intake): +29.8 C (high = +160.0 C, hyst = +150.0 C)
tps53679-i2c-15-61
Adapter: i2c-1-mux (chan_id 6)
PMIC-4 PSU 12V Rail (in1): +12.02 V (crit min = +7.50 V, crit max = +17.00 V)
PMIC-4 PSU 12V Rail (in2): +1.20 V (crit min = +0.80 V, crit max = +1.90 V)
PMIC-4 COMEX 1.2V Rail (out): +0.00 V (crit min = +0.00 V, crit max = +1.55 V)
PMIC-4 Temp 1: +48.8 C (high = +105.0 C, crit = +115.0 C)
PMIC-4 Temp 2: +48.8 C (high = +105.0 C, crit = +115.0 C)
PMIC-4 COMEX 1.2V Rail Pwr (out): 330.08 mW (max = 450.00 W)
pout2: 0.00 W
PMIC-4 COMEX 1.2V Rail Curr (out): +0.01 A (max = +56.00 A, crit max = +63.50 A)
iout2: +0.00 A (max = +18.00 A, crit max = +22.00 A)
tps53679-i2c-5-70
Adapter: i2c-1-mux (chan_id 4)
PMIC-1 PSU 12V Rail (in1): +11.94 V (crit min = +8.50 V, crit max = +15.00 V)
PMIC-1 PSU 12V Rail (in2): +0.80 V (crit min = +0.40 V, crit max = +1.52 V)
PMIC-1 ASIC 0.8V VCORE Rail (out): +1.20 V (crit min = +0.80 V, crit max = +1.52 V)
PMIC-1 Temp 1: +51.2 C (high = +105.0 C, crit = +115.0 C)
PMIC-1 Temp 2: +51.5 C (high = +105.0 C, crit = +115.0 C)
PMIC-1 ASIC 0.8V VCORE Rail Pwr (out): 364.26 mW (max = 450.00 W)
PMIC-1 ASIC 1.2V Rail Pwr (out): 22.28 W
pout2: 10.33 W
PMIC-1 ASIC 0.8V VCORE Rail Curr (out): +0.04 A (max = +24.00 A, crit max = +32.00 A)
PMIC-1 ASIC 1.2V Rail Curr (out): +4.27 A (max = +250.00 A, crit max = +312.00 A)
iout2: +8.61 A (max = +35.00 A, crit max = +43.00 A)
mlxreg_fan-isa-0000
Adapter: ISA adapter
Chassis Fan Drawer-1 Tach 1: 5498 RPM
Chassis Fan Drawer-1 Tach 2: 4908 RPM
Chassis Fan Drawer-2 Tach 1: 5453 RPM
Chassis Fan Drawer-2 Tach 2: 4854 RPM
Chassis Fan Drawer-3 Tach 1: 5409 RPM
Chassis Fan Drawer-3 Tach 2: 4890 RPM
Chassis Fan Drawer-4 Tach 1: 5476 RPM
Chassis Fan Drawer-4 Tach 2: 4836 RPM
pbnoscli#
You can display information about system memory information using the following command:
pbnoscli# show system memory
total used free shared buff/cache available
Mem: 7.7Gi 3.5Gi 2.6Gi 154Mi 1.6Gi 3.7Gi
Swap: 0B 0B 0B
Use the following command to display information about system-reboot:
pbnoscli# show reboot-cause
Hardware - Other (Reset caused by hotswap or halt)
pbnoscli#
pbnoscli# show reboot-cause
User issued 'reboot' command [User: admin, Time: Tue 02 Aug 2022 03:01:03 AM UTC]
pbnoscli#
Use the following command to display information about device SSD:
pbnoscli# show platform ssdhealth
Device Model : StorFly VSFBM4XC030G-MLX1
Health : 99.395%
Temperature : 47C
pbnoscli#
You can display information about docker memory-usage use the following command:
pbnoscli# show docker memory-usage
pbnoscli# show docker memory-usage
CONTAINER ID NAME CPU % MEM USAGE / LIMIT MEM % NET I/O BLOCK I/O PIDS
65f6de2cc45d lldp 0.05% 55.61MiB / 7.669GiB 0.71% 0B / 0B 7.32MB / 127kB 11
6113df8cd655 snmp 5.80% 91.01MiB / 7.669GiB 1.16% 0B / 0B 57.3kB / 98.3kB 10
a6770092098b pmon 20.78% 378.7MiB / 7.669GiB 4.82% 0B / 0B 89.4MB / 139kB 17
29fac3d30c6c sflow 0.04% 39.71MiB / 7.669GiB 0.51% 0B / 0B 2.7MB / 69.6kB 9
a1ba99baa6bb nagr 48.85% 278.2MiB / 7.669GiB 3.54% 0B / 0B 47.8MB / 139kB 15
c1b2207591a6 syncd 2.23% 1.204GiB / 7.669GiB 15.70% 0B / 0B 110MB / 34.8MB 48
96d750ff6689 swss 0.14% 64.02MiB / 7.669GiB 0.82% 0B / 0B 22.9MB / 270kB 40
2c4c2b3c37cc database 5.71% 113.8MiB / 7.669GiB 1.45% 0B / 0B 42.3MB / 65.5kB 11
pbnoscli#
Use the following command to display information about system fans:
pbnoscli# show platform fan
=====================================================================================================================================
ID DRAWER FAN SPEED% DIRECTION PRESENCE STATUS LED TIME STAMP
=====================================================================================================================================
1 drawer1 fan1 21 intake True OK green 20220926 09:17:26
2 drawer1 fan2 19 intake True OK green 20220926 09:17:26
3 drawer2 fan3 21 intake True OK green 20220926 09:17:26
4 drawer2 fan4 19 intake True OK green 20220926 09:17:26
5 drawer3 fan5 21 intake True OK green 20220926 09:17:26
6 drawer3 fan6 19 intake True OK green 20220926 09:17:26
7 drawer4 fan7 21 intake True OK green 20220926 09:17:26
8 drawer4 fan8 18 intake True OK green 20220926 09:17:26
9 N/A psu1_fan1 N/A N/A N/A N/A N/A 20220926 09:17:26
10 N/A psu2_fan1 63 N/A True OK red 20220926 09:17:26
pbnoscli#
Use the following command to display information about device PSU:
pbnoscli# show platform psustatus
============================================================================================================================================
PSU Model Serial Hardware Revision Voltage (V) Current (A) Power (W) Status LED
============================================================================================================================================
PSU 1 N/A N/A N/A N/A N/A N/A NOT OK red
PSU 2 MTEF-PSF-AC-C MT2042X11384 A3 12.035 7.273 88.5 OK red
pbnoscli#
Use the following command to display information about pcie-info:
pbnoscli# show platform pcieinfo
==============================Display PCIe Device===============================
bus:dev.fn 00:00.0 - dev_id=0x6f00, Host bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DMI2 (rev 03)
bus:dev.fn 00:01.0 - dev_id=0x6f02, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 03)
bus:dev.fn 00:01.1 - dev_id=0x6f03, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 03)
bus:dev.fn 00:02.0 - dev_id=0x6f04, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 03)
bus:dev.fn 00:02.2 - dev_id=0x6f06, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 03)
bus:dev.fn 00:03.0 - dev_id=0x6f08, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 03)
bus:dev.fn 00:03.2 - dev_id=0x6f0a, PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 03)
bus:dev.fn 00:05.0 - dev_id=0x6f28, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management (rev 03)
bus:dev.fn 00:05.1 - dev_id=0x6f29, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug (rev 03)
bus:dev.fn 00:05.2 - dev_id=0x6f2a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors (rev 03)
bus:dev.fn 00:05.4 - dev_id=0x6f2c, PIC: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC (rev 03)
bus:dev.fn 00:14.0 - dev_id=0x8c31, USB controller: Intel Corporation 8 Series/C220 Series Chipset Family USB xHCI (rev 05)
bus:dev.fn 00:1c.0 - dev_id=0x8c10, PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #1 (rev d5)
bus:dev.fn 00:1c.7 - dev_id=0x8c1e, PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #8 (rev d5)
bus:dev.fn 00:1d.0 - dev_id=0x8c26, USB controller: Intel Corporation 8 Series/C220 Series Chipset Family USB EHCI #1 (rev 05)
bus:dev.fn 00:1f.0 - dev_id=0x8c54, ISA bridge: Intel Corporation C224 Series Chipset Family Server Standard SKU LPC Controller (rev 05)
bus:dev.fn 00:1f.2 - dev_id=0x8c02, SATA controller: Intel Corporation 8 Series/C220 Series Chipset Family 6-port SATA Controller 1 [AHCI mode] (rev 05)
bus:dev.fn 00:1f.3 - dev_id=0x8c22, SMBus: Intel Corporation 8 Series/C220 Series Chipset Family SMBus Controller (rev 05)
bus:dev.fn 03:00.0 - dev_id=0x6f50, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 0
bus:dev.fn 03:00.1 - dev_id=0x6f51, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 1
bus:dev.fn 03:00.2 - dev_id=0x6f52, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 2
bus:dev.fn 03:00.3 - dev_id=0x6f53, System peripheral: Intel Corporation Xeon Processor D Family QuickData Technology Register DMA Channel 3
bus:dev.fn 06:00.0 - dev_id=0xcf6c, Ethernet controller: Mellanox Technologies MT53100 [Spectrum-2]
bus:dev.fn 08:00.0 - dev_id=0x1533, Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
bus:dev.fn ff:0b.0 - dev_id=0x6f81, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.1 - dev_id=0x6f36, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.2 - dev_id=0x6f37, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 03)
bus:dev.fn ff:0b.3 - dev_id=0x6f76, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug (rev 03)
bus:dev.fn ff:0c.0 - dev_id=0x6fe0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0c.1 - dev_id=0x6fe1, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.0 - dev_id=0x6ff8, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.4 - dev_id=0x6ffc, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.5 - dev_id=0x6ffd, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:0f.6 - dev_id=0x6ffe, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 03)
bus:dev.fn ff:10.0 - dev_id=0x6f1d, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 03)
bus:dev.fn ff:10.1 - dev_id=0x6f34, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 03)
bus:dev.fn ff:10.5 - dev_id=0x6f1e, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:10.6 - dev_id=0x6f7d, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:10.7 - dev_id=0x6f1f, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 03)
bus:dev.fn ff:12.0 - dev_id=0x6fa0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 03)
bus:dev.fn ff:12.1 - dev_id=0x6f30, Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 03)
bus:dev.fn ff:13.0 - dev_id=0x6fa8, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 03)
bus:dev.fn ff:13.1 - dev_id=0x6f71, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 03)
bus:dev.fn ff:13.2 - dev_id=0x6faa, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.3 - dev_id=0x6fab, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.4 - dev_id=0x6fac, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.5 - dev_id=0x6fad, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 03)
bus:dev.fn ff:13.6 - dev_id=0x6fae, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast (rev 03)
bus:dev.fn ff:13.7 - dev_id=0x6faf, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 03)
bus:dev.fn ff:14.0 - dev_id=0x6fb0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control (rev 03)
bus:dev.fn ff:14.1 - dev_id=0x6fb1, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control (rev 03)
bus:dev.fn ff:14.2 - dev_id=0x6fb2, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error (rev 03)
bus:dev.fn ff:14.3 - dev_id=0x6fb3, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error (rev 03)
bus:dev.fn ff:14.4 - dev_id=0x6fbc, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.5 - dev_id=0x6fbd, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.6 - dev_id=0x6fbe, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:14.7 - dev_id=0x6fbf, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 03)
bus:dev.fn ff:15.0 - dev_id=0x6fb4, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control (rev 03)
bus:dev.fn ff:15.1 - dev_id=0x6fb5, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control (rev 03)
bus:dev.fn ff:15.2 - dev_id=0x6fb6, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error (rev 03)
bus:dev.fn ff:15.3 - dev_id=0x6fb7, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error (rev 03)
bus:dev.fn ff:1e.0 - dev_id=0x6f98, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.1 - dev_id=0x6f99, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.2 - dev_id=0x6f9a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.3 - dev_id=0x6fc0, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1e.4 - dev_id=0x6f9c, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1f.0 - dev_id=0x6f88, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
bus:dev.fn ff:1f.2 - dev_id=0x6f8a, System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 03)
pbnoscli#
Use the following command to display information about running services on the device:
pbnoscli# show services
lldp docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.3 30388 24176 pts/0 Ss+ 08:09 0:02 /usr/bin/python3 /usr/local/bin/supervisord
root 12 0.0 0.2 25616 19104 pts/0 S 08:09 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name lldp
root 15 0.0 0.0 223808 5616 pts/0 Sl 08:09 0:00 /usr/sbin/rsyslogd -n -iNONE
_lldpd 23 0.0 0.0 28364 7692 pts/0 S 08:09 0:00 lldpd: monitor.
_lldpd 25 0.0 0.0 28612 3820 pts/0 S 08:09 0:01 lldpd: 2 neighbors.
root 32 0.0 0.2 105268 21700 pts/0 Sl 08:09 0:03 python3 -m lldp_syncd
root 36 0.0 0.2 34608 22280 pts/0 S 08:09 0:00 python3 /usr/bin/lldpmgrd
snmp docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.3 33644 24436 pts/0 Ss+ 08:12 0:01 /usr/bin/python3 /usr/local/bin/supervisord
root 10 0.0 0.2 31100 19440 pts/0 S 08:12 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name snmp
root 18 0.0 0.0 223808 5616 pts/0 Sl 08:12 0:00 /usr/sbin/rsyslogd -n -iNONE
Debian-+ 22 0.9 0.2 37484 19024 pts/0 S 08:12 0:35 /usr/sbin/snmpd -f -LS4d -Lf /var/log/snmpd.log -u Debian-snmp -g Debian-snmp -I -smux -p /run/snmpd.pid
root 23 4.0 0.4 348084 36636 pts/0 Sl 08:12 2:34 python3 -m sonic_ax_impl
pmon docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.3 30700 24312 pts/0 Ss+ 08:08 0:02 /usr/bin/python3 /usr/local/bin/supervisord
root 47 0.0 0.2 25636 19068 pts/0 S 08:08 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name pmon
root 50 0.0 0.0 223808 3632 pts/0 Sl 08:08 0:00 /usr/sbin/rsyslogd -n -iNONE
root 56 0.3 1.0 213980 86084 pts/0 Sl 08:08 0:13 python3 /usr/local/bin/xcvrd
root 58 0.3 1.0 137540 82448 pts/0 S 08:08 0:13 python3 /usr/local/bin/psud
root 60 0.0 1.0 138596 83760 pts/0 S 08:08 0:00 python3 /usr/local/bin/syseepromd
root 61 0.2 1.0 138960 84516 pts/0 S 08:08 0:10 python3 /usr/local/bin/thermalctld
root 63 0.1 1.0 138840 84440 pts/0 S 08:08 0:06 python3 /usr/local/bin/pcied
root 64 0.1 0.7 138960 64100 pts/0 S 08:08 0:05 python3 /usr/local/bin/thermalctld
root 70 0.0 0.0 59092 1076 ? Ss 08:08 0:00 /usr/sbin/sensord -f daemon
root 408 0.0 0.8 214556 71224 pts/0 S 08:09 0:00 python3 /usr/local/bin/xcvrd
sflow docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.2 30256 23992 pts/0 Ss+ 08:08 0:01 /usr/bin/python3 /usr/local/bin/supervisord
root 10 0.0 0.2 25612 19032 pts/0 S 08:08 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name sflow
root 13 0.0 0.0 223808 5424 pts/0 Sl 08:08 0:00 /usr/sbin/rsyslogd -n -iNONE
root 17 0.0 0.1 88328 8124 pts/0 Sl 08:08 0:00 /usr/bin/sflowmgrd
root 18 0.0 0.2 30752 20532 pts/0 S 08:08 0:00 python3 /usr/bin/port_index_mapper.py
nagr docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.2 59008 21160 pts/0 Ss+ 08:08 0:02 /usr/bin/python /usr/local/bin/supervisord
root 10 4.9 1.2 486580 103668 pts/0 Sl 08:08 3:22 /usr/bin/python3 /gemini/NTPRest/naggc.py
root 11 0.0 0.2 60380 18508 pts/0 S 08:08 0:00 /usr/bin/python3 /usr/bin/lag.py
root 12 0.0 0.2 60360 18652 pts/0 S 08:08 0:00 /usr/bin/python3 /usr/bin/netlink_route.py
root 13 0.0 0.2 206576 17192 pts/0 Sl 08:08 0:00 /usr/bin/python3 /usr/bin/toolhc.py
root 14 0.0 0.2 60356 18240 pts/0 S 08:08 0:00 /usr/bin/python3 /usr/bin/netlink_poll.py
root 21 0.0 0.0 262992 3420 pts/0 Sl 08:08 0:00 /usr/sbin/rsyslogd -n
syncd docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.3 30568 24232 pts/0 Ss+ 08:08 0:01 /usr/bin/python3 /usr/local/bin/supervisord
root 10 0.0 0.2 25704 19316 pts/0 S 08:08 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name syncd
root 14 0.0 0.0 223808 5576 pts/0 Sl 08:08 0:00 /usr/sbin/rsyslogd -n -iNONE
root 19 1.7 1.5 1784640 128056 pts/0 Sl 08:08 1:09 /usr/bin/syncd -u -s -p /tmp/sai.profile
root 44 5.6 11.1 1365284 895996 pts/0 Sl 08:08 3:49 sx_sdk --logger libsai.so
root 66 0.0 1.9 343036 155164 pts/0 Sl 08:08 0:01 /usr/bin/python3 /usr/bin/mellanox_nagg_asic.py
swss docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.1 0.3 30652 24500 pts/0 Ss+ 08:07 0:05 /usr/bin/python3 /usr/local/bin/supervisord
root 26 0.0 0.2 25620 19040 pts/0 S 08:07 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name swss
root 29 0.0 0.0 223808 3596 pts/0 Sl 08:07 0:00 /usr/sbin/rsyslogd -n -iNONE
root 34 0.0 0.0 81260 4960 pts/0 Sl 08:07 0:00 /usr/bin/portsyncd
root 39 0.0 0.2 403316 22456 pts/0 Sl 08:08 0:03 /usr/bin/orchagent -d /var/log/swss -b 8192 -s
root 64 0.0 0.1 88384 8176 pts/0 Sl 08:08 0:00 /usr/bin/coppmgrd
root 76 0.0 0.0 3964 2928 pts/0 S 08:08 0:00 /bin/bash /usr/bin/arp_update
root 77 0.0 0.0 81132 4404 pts/0 Sl 08:08 0:00 /usr/bin/neighsyncd
root 79 0.0 0.1 88448 8548 pts/0 Sl 08:08 0:00 /usr/bin/vlanmgrd
root 81 0.0 0.1 88472 8564 pts/0 Sl 08:08 0:00 /usr/bin/intfmgrd
root 83 0.0 0.1 88412 8332 pts/0 Sl 08:08 0:00 /usr/bin/portmgrd
root 85 0.0 0.1 88508 10240 pts/0 Sl 08:08 0:00 /usr/bin/buffermgrd -l /usr/share/sonic/hwsku/pg_profile_lookup.ini
root 98 0.0 0.1 88444 8420 pts/0 Sl 08:08 0:00 /usr/bin/vrfmgrd
root 104 0.0 0.1 88344 8248 pts/0 Sl 08:08 0:00 /usr/bin/nbrmgrd
root 112 0.0 0.1 88472 8332 pts/0 Sl 08:08 0:00 /usr/bin/vxlanmgrd
root 117 0.0 0.0 81176 4796 pts/0 Sl 08:08 0:00 /usr/bin/fdbsyncd
root 122 0.0 0.1 88416 8244 pts/0 Sl 08:08 0:00 /usr/bin/tunnelmgrd
root 153 0.0 0.0 5668 1684 pts/0 S 08:08 0:00 /usr/sbin/ndppd
root 6652 0.0 0.0 2524 744 pts/0 S 09:13 0:00 sleep 300
database docker
---------------------------
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 1 0.0 0.2 30248 23700 pts/0 Ss+ 08:07 0:01 /usr/bin/python3 /usr/local/bin/supervisord
root 38 0.0 0.2 25612 19032 pts/0 S 08:07 0:00 python3 /usr/bin/supervisor-proc-exit-listener --container-name database
root 39 0.0 0.0 223808 5616 pts/0 Sl 08:07 0:00 /usr/sbin/rsyslogd -n -iNONE
root 40 4.0 0.7 110832 59672 pts/0 Sl 08:07 2:46 /usr/bin/redis-server 127.0.0.1:6379
pbnoscli#
Use the following command to display information about device temperature sensors:
pbnoscli# show platform temperature
=============================================================================================================================================
Sensor Temperature Warning High TH Low TH Critical High TH Critical Low TH Timestamp
=============================================================================================================================================
xSFP module 3 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 7 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 27 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
CPU Core 0 Temp 58.0 False 82.0 N/A 104.0 N/A 20220926 09:22:26
xSFP module 9 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 14 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 19 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 23 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 30 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 15 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
ASIC 53.0 False 105.0 N/A 120.0 N/A 20220926 09:22:26
CPU Core 1 Temp 59.0 False 82.0 N/A 104.0 N/A 20220926 09:22:26
Ambient Fan Side Temp 29.812 False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 4 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 26 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 12 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 5 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
PSU-2 Temp 26.75 False 60.0 N/A N/A N/A 20220926 09:22:26
xSFP module 24 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
CPU Pack Temp 59.0 False 82.0 N/A 104.0 N/A 20220926 09:22:26
xSFP module 10 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
Ambient Port Side Temp 36.437 False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 17 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 1 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 21 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 31 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 11 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
PSU-1 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 8 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 18 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 29 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 32 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
Ambient COMEX Temp 48.125 False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 28 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 2 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 20 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 16 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 13 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 25 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
xSFP module 6 Temp N/A False N/A N/A N/A N/A 20220926 09:22:26
xSFP module 22 Temp N/A False N/A N/A N/A N/A 20220926 09:22:27
pbnoscli#